GKS Spring-Loaded Test Probe
|
Series
|
Grid
in Mil
|
Grid
in mm
|
Max. Stroke
in mm
|
Working Stroke
in mm
|
Current Rating
in (A)
|
PDF
|
STEP 3-D Files (ZIP)
|
|
E-TYPE Test Probes For Lead-Free Contacting |
|||||||
| E-050 | 50 | 1,27 | 5 | 4,3 | 3 | E-050 | E-050 |
| E-075 | 75 | 1,91 | 5 | 4,3 | 4 | E-075 | E-075 |
| E-100 | 100 | 2,54 | 5 | 4,3 | 5 | E-100 | E-100 |
| E-422 | 422 | 2,54 | 8 | 6,4 | 5 | E-422 | |
|
In-Circuit / Functional Test (ICT / FCT) |
|||||||
| GKS-040 | 40 | 1 | 6,35 | 4,3 | 2 | GKS-040 | |
| GSK-050 | 50 | 1,27 | 6,35 | 4,3 | 3 | GKS-050 | GKS-050 |
| GKS-015 | 50 | 1,27 | 10 | 8 | 3 | GKS-015 | |
|
GKS-075
|
75
|
1,91
|
4,3
|
6,35
|
3 – 4
|
||
|
GKS-075
|
75
|
1,91
|
4,3
|
6,35
|
3 – 4
|
||
|
GKS-100
|
100
|
2,54
|
4,3
|
6,35
|
5 – 8
|
||
|
GKS-100
|
100
|
2,54
|
4,3
|
6,35
|
5 – 8
|
||
|
GKS-035
|
75 | 1,91 | 10 | 8 | 3 – 4 | GKS-035 | GKS-035 |
| GKS-135 | 100 | 2,54 | 11,5 | 9,3 | 5 – 8 | GKS-135 | GKS-135 |
| GKS-101 | 75 | 1,91 | 5,3 | 4 | 3 – 4 | GKS-101 | |
| GKS-001 | 75 | 1,91 | 2,4 | 2 | 3 – 4 | GKS-001 | |
| GKS-002 | 100 | 2,54 | 4,1 | 2,7 | 5 – 8 | GKS-002 | GKS-002 |
| GKS-003 | 125 | 3,18 | 6,35 | 4,4 | 6 | GKS-003 | GKS-003 |
| GKS-004 | 187 | 4,75 | 6,35 |
4,4 |
7 | GKS-004 | GKS-004 |
| GKS-005 | 187 | 4,75 | 6,35 | 4,4 | 8 | GKS-005 | GKS-005 |
| KS-040 WL | 40 | 1 | 2 | KS-040 WL | |||
| KS-550 WL | 50 | 1,27 | 3 | KS-550 WL | |||
| KS-075 WL | 75 | 1,91 | 4 | KS-075 WL | |||
| KS-100 WL | 100 | 2,54 | 5 | KS-100 WL | |||
|
Bead Probes |
|||||||
| GKS-050 | 50 | 1,27 | 6,35 | 4,3 | 3 | GKS-050 | GKS-050 |
| GKS-075 | 75 | 1,91 | 6,35 | 4,3 | 3 – 4 | GKS-075 | GKS-075 |
| GKS-100 | 100 | 2,54 | 6,35 | 4,3 | 5 – 8 | GKS-100 | GKS-100 |
| GKS-135 | 135 | 2,54 | 11,35 | 9,3 | 5 – 8 | GKS-135 | |
|
Fine Pitch Test Probes 25 MIL or Less |
|||||||
| GKS-038 | 25 | 0,64 | 2,5 | 2 | 1 | GKS-038 | GKS-038 |
| GKS-041 | 28 | 0,7 | 3,5 | 2,5 | 2 | GKS-041 | GKS-041 |
| GLS-061 | 30 | 0,8 | 3,5 | 2,5 | 2 | GKS-061 | GKS-061 |
| GKS-080 | 40 | 1 | 3 | 3 | 3,8 | GKS-080 | GKS-080 |
| GKS-081 | 40 | 1 | 7,5 | 5,5 | 3 | GKS-081 | GKS-081 |
| GKS-069 | 50 | 1,27 | 2,8 | 2,2 | 3 | GKS-069 | GKS-069 |
| GKS-079 | 50 | 1,27 | 1,2 | 1 | 3 | GKS-079 | GKS-079 |
| GKS-181 | 50 | 1,27 | 7,5 | 5,5 | 3 | GKS-181 | GKS-181 |
|
Test Probes 40 MIL |
|||||||
| GKS-040 | 40 | 1 | 6,35 | 4,3 | 2 | GKS-040 | |
| GKS-080 | 40 | 1 | 3,8 | 3 | 3 | GKS-080 | GKS-080 |
| GKS-081 | 40 | 1 | 7,5 | 5,5 | 3 | GKS-081 | GKS-081 |
|
Interface Test Probes |
|||||||
| GKS-945 | 100 | 2,54 | 3,1 | 2,6 | 5 | GKS-945 | GKS-945 |
| GKS-946 | 100 | 2,54 | 3,9 | 3,2 | 5 | GKS-946 | GKS-946 |
| GKS-938 | 100 | 2,54 | 4,3 | 3,6 | 5 | GKS-938 | GKS-938 |
|
GKS-100 Series for Teradyne |
100 | 2,54 | 6,35 | 4,3 | 5 | GKS-100 307 | GKS-100 307 |
|
GKS-100 Series for Agilent / HP 3070 |
200 | 5,08 | 6,35 | 4,3 | 5 | GKS-100 306 | GKS-100 306 |
|
GKG-100 Series for Factron 300/700 |
100 | 2,54 | 4 | 3 | 5 | GKS100-357 | GKS-100 357 |
| GKS 925 TJA | 200 | 5 | 6 | 5 | 5 | GKS-925 TJA | |
| GKS-416 | 180 | 4,5 | 11,5 | 9,2 | GKS-416 | GKS-416 | |
| GKS-102 | 200 | 5 | 6,5 | 4,8 | GKS-102 | GKS-102 | |
| GKS-504 | 180 | 4,5 | 14 | 11,2 | 5 – 15 | GKS-504 | GKS-504 |
| GKS-414 | 315 | 8 | 11,2 | 9,6 | 5 – 8 | GKS-414 | GKS-414 |
|
Battery Test Probes
|
|||||||
| GKS-967 | 120 | 3 | 1,2 | 1 | 5 -8 | GKS-967 | GKS-967 |
| GKS-970 | 120 | 3 | 3,3 | 2,8 | 5 – 8 | GKS- 970 | GKS-970 |
| GKS-961 | 75 | 1,91 | 1,3 | 1 | 2 | GKS-961 | GKS-961 |
|
Special Test Probes |
|||||||
| GKS-004 | 187 | 4,75 | 6,35 | 4,4 | 7 | GKS-004 | GKS-004 |
| GKS-005 | 187 | 4,75 | 6,35 | 4,4 | 8 | GKS-005 | GKS-005 |
| GKS-113 | 157 | 4 | 5,3 | 4 | 5 – 8 | GKS-113 | GKS-113 |
| GKS 913 | 157 | 4 | 3,5 | 2,8 | 5 – 8 | GKS-913 | GKS-913 |
| GKS 913 M | 160 | 4 | 3,5 | 2,8 | 5 – 8 | GKS-913 M | |
| GKS-103/103 M | 157 | 4 | 6 | 4,8 | 5 – 8 | GKS-103/103 M | GKS-103/103 M |
| GKS-503/503 M | 157 | 4 | 7 | 5,6 | 5 – 15 | GKS-503/503 M | GKS-503/503 M |
| GKS-364 | 260 | 6,5 | 5 | 4 | 15 | GKS-364 | |
| GKS-365 | 250 | 6,5 | 4 | 3,2 | 8 | GKS-365 | |
| GKS-366 | 366 | 6,5 | 10 | 8 | 5 – 8 | GKS-366 | |
| GKS-725 | 100 | 2,54 | 6 | 4,8 | 5 – 8 | GKS-725 | GKS-725 |
|
GKS-713 |
180 | 4,5 | 5 | 4 | 5 – 8 | GKS-713 | GKS-713 |
|
Metric Standard Test Probes (2,54 or greater) |
|||||||
| KS-112 | 100 | 2,54 | 16 | KS-112 | KS-112 | ||
| GKS-112 | 100 | 2,54 | 5,3 / 8 | 4 / 6,4 | 5 – 8 | GKS-112 | GKS-112 |
| GKS-912 | 100 | 2,54 | 5 | 4 | 5 – 8 | GKS-912 | GKS-912 |
| GKS-422 | 100 | 2,54 | 8 | 6,4 | 5 – 8 | GKS-422 | GKS-422 |
| GKS-412 | 100 | 2,54 | 9,8 | 8 | 5 – 8 | GKS-412 | GKS-412 |
| GKS-204 /204 M | 100 | 2,54 | 10 | 8 | 5 – 8 | GKS-204/204 M | GKS-204/204 M |
| GKS-102 | 100 | 2,54 | 6,5 | 4,8 | 5 – 8 | GKS-102 | GKS-102 |
| GKS-502 | 100 | 2,54 | 7 | 5,6 | 5 – 15 | GKS-502 | GKS-502 |
| GKS-113 | 157 | 4 | 5,3 | 4 | 5 – 8 | GKS-113 | GKS-113 |
| GKS-913 | 157 | 4 | 3,5 | 2,8 | 5 – 8 | GKS-913 | GKS-913 |
| GKS-103/103 M | 157 | 4 | 6 | 4,8 | 5 – 8 | GKS-103/103 M | GKS-103/103 M |
| GKS-503/503 M | 157 | 4 | 7 | 5,6 | 5 – 15 | GKS-503/503 M | GKS-503/503 M |
| GKS-364 | 260 | 6,5 | 5 | 4 | 15 | GKS-364 | |
| GKS-365 | 260 | 6,5 | 4 | 3,2 | 8 | GKS-365 | |
| GKS-366 | 366 | 6,5 | 10 | 8 | 5 – 8 | GKS-366 | |
|
Solderable Test Probes GKS |
|||||||
| GKS-941 | 75 | 1,91 | 4 | 3,2 | 5 – 8 | GKS-941 | GKS-941 |
| GKS-064 | 100 | 2,54 | 1,7 | 1,4 | 5 – 8 | GKS-064 | GKS-064 |
| GKS-986 | 100 | 2,54 | 5 | 3 | 5 – 8 | GKS-986 | GKS-986 |
Design of Test Probes
![]() |
Spring-loaded Test Probes (GKS) normally consist of 3 individual components. All components must be manufactured with the type of precision, which is demanded by the micro-electronics industry.
The Plunger with the contacting zone is available in a large choice of tip-styles. It must provide the smallest possible contact resistance between the Test Probe and test point, to ensure that measurement results are not distorted. The most common plunger materials are Steel and CuBe – both of which are hardened. For very passive tip-styles brass is also used.
The Spring provides the necessary contact pressure and this even after several hundred thousand strokes (testing cycles). The specified spring-forces are reached with the recommended working stroke and are subject to a tolerance range of +/- 10-15%; this being due to the parameter restrictions when designing and manufacturing springs for such small components.
For easy measurement of the spring forces, common spring-force measuring gauges are used.
The Barrel accommodates the plunger and the spring. The actual measurement signal flows via the barrel to the Receptacle. To improve the smooth movement, after gold-plating the barrel is treated with a very thin organic protective layer.


English
Czech
Slovak
Croatian
Hungarian
Polish
Romanian
Russian
Serbian
Ukrainian